Expansion module to VC Node CU to connect current loop inputs.
- 16 inputs for current loop (4-20mA)
- Synchronous measurement of all channels
- Sync with VC node CU
| Product features | ||
| Number of channels | 16 parallel | |
| Total sample rate | 1,6 kHz (100 Hz for each channel) | |
| Connection |
WAGO spring clip J1 (A1…A8) und J2 (A9…A16) Current loop input (4-20mA) | |
| Resolution | 16 Bit | |
| Expansion capabilities | 1 module per VC Node CU | |
| Case | Plastic case (107,6 x 90,0 x 62,2 mm) | |
| Memory | 512kB SDRAM | |
| Fields of application | ||
| Temperature range | 0 °C … +70 °C | |
| Humidity | 10 % … 90 % (don’t fog) | |
| Protection type | IP 20 | |
| Electrical data | ||
| Electrical design | DC via data bus from VC Node CU | |
| Operating voltage | 5V DC | |
| Current consumption | < 100 mA | |
| Current consumption | III | |
| Reverse voltage protection | Yes | |
| Galvanic isolation | Yes | |
| Measurement range | ||
| Measuring frequency | 0,01 Hz … 100 Hz | |